Metering Alarm
The alarm is applicable only to Mediant VE.
acMeteringAlarm
Alarm |
acMeteringAlarm |
||||||||
---|---|---|---|---|---|---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.146 |
||||||||
Description |
The alarm is sent when the device fails to communicate with the metering API. The device needs to communicate with the Marketplace API when using AudioCodes' Metered License model to license the SBC, which is based on the device's usage (in minutes). |
||||||||
Default Severity |
Warning |
||||||||
Source Varbind Text |
Board#1 (SystemMO) |
||||||||
Event Type |
communicationsAlarm |
||||||||
Probable Cause |
communicationsProtocolError |
||||||||
Alarm Severity |
Condition |
Text |
Corrective Action |
||||||
Warning |
The device is unable to send a usage report to the metering service after it initially connected to it. |
"No connection to metering API – service will be down in <hours> hours" |
Check the network configuration and make sure that the device has the appropriate environment as required for the metering offer. |
||||||
Critical |
- or -
|
"Service down due to no connection to metering API" |
Check the network configuration and make sure that the device has the appropriate environment as required for the metering offer. |
||||||
Critical |
The device is blocked by the metering license server. |
“Service is blocked by metering license server” |
- |
||||||
Cleared |
The device successfully communicates with the metering API. |
"Device succeeds to communicate with metering API" |
- |